68
8. Set Skin
Press the “skin” option button or turn the “Universal” knob to select
“Classical”, “Modern”, “Traditional” or “Succinct”.
2.10.1 X-Y Format
Use the XY format to analyze phase differences, such as those represented
by Lissajous patterns. The format plots the voltage on channel 1 against the
voltage on channel 2 or plots the voltage on channel 3 against the voltage on
channel 4, where channel 1(or channel 3) is the horizontal axis and channel 2
(or channel 4)is the vertical axis. The oscilloscope uses the untriggered
Sample acquisition mode and displays data as dots.
XY mode has a breakthrough that trad oscilloscopes restrict sampling rate at
1MSa/s
SDS1000C/D series support 5KSa/s 200MSa/s (1-2.5-5 sequence)
adjusted;
SDS1000CM/CN series support 25KSa/s100MSa/s (1-2.5-5 sequence)
adjusted ; SDS1000CE series support 5KSa/s1GSa/s (1-2.5-5 sequence)
adjusted and SDS1000CF/CFL series support 10Ksa/s1GSa/s (1-2.5-5
sequence) adjusted.
Operation steps
Channel 1or Channel 3“Volt/div”and vertical “POSITION” set up the
horizontal scale and position.
Channel 2 or Channel 4“Volt/div”and vertical “POSITION” set up
the horizontal scale and position.
NoteThe oscilloscope can capture a waveform in normal YT mode
at any sampling rate. You can view the same waveform in XY mode.
To do so, stop the acquisition and change the display format to XY.