70
maximum values of a waveform and knew you had a scale factor of
100mV/div, then you could easily calculate your peak-to-peak voltage as
follows:
5 divisions x 100 mV/division = 500 mV.
2.11.2 Cursor Measurement
Picture 2-50 displays the cursor button on the front-panel for this menu.
Cursors Button
Picture 2.11-1
Press the “CURSORS” button to display the “Cursor” Menu.
The cursor measurement has three modes: Manual, Track and Auto Measure.
Manual Mode
Table 2-32 Manual cursor function menu:
Option Setting Instruction
Cursor
Mode
Manual In this menu, set the manual cursor
measure.
Type Voltage
Time
Use cursor to measure voltage parameters.
Use cursor to measure time parameters.
Source CH1
CH2
CH3
CH4
MATH/FFT
REFA
REFB
REFC
REFD
Select input signal channel.
Cur A
Select this optionturn the “Universal” knob
to adjust cursor A.
Cur B
Select this optionturn the “Universal” knob
to adjust cursor B.
In this mode, the screen displays two horizontal parallel cursors or vertical